Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/16285
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.advisorZanesco, Izete
dc.contributor.advisorMoehlecke, Adriano
dc.contributor.authorRamanauskas, Luiza Ferreira da Costa
dc.date.accessioned2019-11-26T12:02:05Z-
dc.date.available2019-11-26T12:02:05Z-
dc.date.issued2019pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/16285-
dc.description.abstractOs sistemas fotovoltaicos (FV) instalados em zona rural estão se tornando uma realidade no Brasil para reduzir os custos de produção envolvidos nesta atividade. O objetivo deste trabalho é analisar parâmetros que afetam a produção de energia elétrica de um sistema FV de 20 kWp conectado à rede elétrica de baixa tensão instalado em propriedade rural associada à cooperativa agroindustrial no município de Assis Chateaubriand, cuja atividade é a criação de proteína animal (aves). Determinou-se que o arranjo FV seria instalado sobre o telhado do aviário com orientação do telhado. Ao caracterizar eletricamente os módulos FVs de silício cristalino, constatou-se que o valor médio da potência dos 60 dispositivos é 1,9 % superior ao valor apresentado pelo fabricante, que é de 340 W. O sistema FV está constituído de quatro painéis com 15 módulos FVs cada um, associados em série. A potência total instalada foi de 20,8 kWp.A potência máxima variou de 17 kW para kW e 11 kW no meio dia solar em um dia com céu limpo próximo ao solstício de verão, equinócio de outono e solstício de inverno. Observou-se que o inversor apresentou problemas reduzindo a potência AC de saída, no dia próximo ao equinócio, quando o aviário estava em período de produção. Para um período com irradiância solar similar e maior que 540 W/m2, constatou-se que ocorre redução da temperatura dos módulos FVs de 2,6 ºC com o aumento da velocidade do vento de 1 m/s. A produção de energia elétrica, no mês de junho foi da ordem de 30 % e 50 % a menos que a energia produzida no mês de março e dezembro, respectivamente. O maior valor diário do desempenho global foi de 86 % e ocorreu em dias nos meses de verão e inverno e é igual ao valor simulado. A produtividade mensal foi de 160 kWh/kW, 113 kWh/kW e 81 kWh/kW para o mês de verão outono e inverno, respectivamente. O tempo de retorno do sistema FV estimado é de 8 anos.pt_BR
dc.description.abstractPhotovoltaic (PV) systems installed in rural areas are becoming a reality in Brazil to reduce production costs involved in this activity. The objective of this work is to analyze parameters that affect the output power of a 20 kWp on-grid photovoltaic systems connected to the low voltage installed in rural property associated with the agroindustrial cooperative in the municipality of Assis Chateaubriand, and the activity is the poultry production. It was determined that PV system array would be installed on the roof of the aviary with orientation of the roof. By characterizing the crystalline silicon PV modules, the average value of the power of the 60 devices was 1.9 % higher than the value presented by the manufacturer datasheet, which is 340 W. The PV system consists of four panels with 15 modules each, associated in series. The total installed power was 20.8 kWp. The maximum output power ranged from 17 kW to 15 kW and 11 kW at solar noon on a clear day near the summer solstice, autumnal equinox and winter solstice. The inverter presented problems that reduced the output AC power, in the day next to the equinox, when the aviary was in production period. For a period with similar solar irradiance and greater than 540 W/m², there is a reduction of the temperature of the PV modules of 2.6 ºC with the increase of the wind speed of 1 m/s.The electrical energy in the month of June was of around 30 % and 50 % less than the electrical energy produced in March and December, respectively. The highest daily value of performance ratio was 86 % and occurred in days in the summer and winter months and is equal to the simulated value. The monthly yield was 160 kWh/kW, 113 kWh/kW and 81 kWh/kW for the summer, autumn and winter months, respectively. The estimated payback for the PV system is 8 years.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.rightsopenAccessen_US
dc.subjectENERGIA SOLARpt_BR
dc.subjectSISTEMAS FOTOVOLTAICOSpt_BR
dc.subjectCÉLULAS SOLARESpt_BR
dc.subjectENGENHARIA DE MATERIAISpt_BR
dc.titleAvaliação de parâmetros que afetam a produção de energia elétrica em um sistema fotovoltaico em propriedade ruralpt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia e Tecnologia de Materiaispt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2019pt_BR
dc.publisher.placePorto Alegrept_BR
Aparece en las colecciones:Dissertação e Tese

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
000496579-Texto+completo-0.pdfTexto completo1,67 MBAdobe PDFAbrir
Ver


Todos los ítems en el Repositorio de la PUCRS están protegidos por derechos de autor, con todos los derechos reservados, y están bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional. Sepa más.