Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/3280
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.advisorHübler, Robertoen_US
dc.contributor.authorTrevizan, Jorge Dal Pozzoen_US
dc.date.accessioned2013-08-07T18:54:14Z-
dc.date.available2013-08-07T18:54:14Z-
dc.date.issued2006pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/3280-
dc.description.abstractEste trabalho visa avaliar a cobertura parcial do revestimento poroso plasma spray (PS) utilizado em implantes de quadril. Foram testados diversos implantes comerciais, novos e usados, nacionais e importados dos EUA e Portugal, considerados como padrão ouro. Os resultados, dos implantes nacionais, foram analisados antes e, sugerido um jateamento de areia, anterior à deposição, objetivando aumentar a adesão do revestimento ao metal base. Novos testes foram realizados para comprovar a eficiência da otimização do processo, na aderência da camada de PS. As orientações foram determinadas pelas normas ASTM F 1854-01 e os testes de tração e análise química, segundo as normas ASTM E 3, E 883, C 633-01, ISO 468, ISO 5832. As avaliações foram feitas utilizando microscopia óptica (MO), microscópio eletrônico de varredura (SEM), espectroscopia de raio X por energia dispersa (EDS) e ensaios de tração, com máquina universal de ensaios. Comprovou-se que a adesão ao novo implante obteve um acréscimo superior a 100%, que a camada de PS diminuiu, em aproximadamente 21%, e o volume vazio diminuiu próximo de 16%. Também foi verificado a osteointegração (osso x implante), após noventa dias implantado, e constatado que ela realmente ocorre e é confiável.pt_BR
dc.description.abstractThis search aim for evaluate the partial cover from the plasma spray coating (PS) used in hip implants. Various commercial implants, new and used, national and imported from USA and Portugal, considered gold standard, were tested. The results of the national implants were before analyzed and was suggested a sandblast previous the deposition with the objective of increase the adhesion from coating to base metal. New tests were done to prove the efficiency in the optimization of process, in the adherence of PS layer. The orientations were determined by ASTM F 1854-01 and the traction tests and chemistry analysis, according to the norms ASTM E3, E883, C 633-01, ISO 468, ISO 5832. The evaluations were done using optical microscopy (MO), scanning electron microscopy (SEM), spectroscopy of X-ray by dispersive energy (EDS) and traction tests, with universal testing machine. It was proved that the adhesion to the new implant got better in 100%, the PS layer decreased in approximately 21% and the empty volume decreased in 16%. It was also verified the osseointegration (bone x implant), after ninety days implanted and realized that it actually occur and it’s trustful.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.subjectENGENHARIA DE MATERIAISpt_BR
dc.subjectPRÓTESE DE QUADRILpt_BR
dc.subjectENGENHARIA BIOMÉDICApt_BR
dc.subjectMATERIAIS - TESTESpt_BR
dc.titleAnálise estereográfica de implantes de quadril recobertos por plasma spraypt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia e Tecnologia de Materiaispt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2006pt_BR
dc.publisher.placePorto Alegrept_BR
Aparece en las colecciones:Dissertação e Tese