Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/898
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.authorArieta, Luciana Correa-
dc.contributor.authorKrause, Ramon-
dc.contributor.authorRockenbach, Maria Ivete Bolzan-
dc.contributor.authorVeeck, Elaine Bauer-
dc.date.accessioned2012-04-25T14:30:48Z-
dc.date.available2012-04-25T14:30:48Z-
dc.date.issued2010-
dc.identifier.issn0001-6365en_US
dc.identifier.urihttp://hdl.handle.net/10923/898-
dc.description.abstractThe objective of this study was to compare conventional and digital radiographs to measure root canals. Fifty permanent single-canal teeth were employed. The roots were placed on the film or on the storage phosphor plate on their longest axes. And they were perpendicularly exposed to the x-ray beam in a distance of 30 cm with the exposure time of 0.08 s. The conventional radiographs were obtained using periapical film #2 (InSight, Kodak). They were measured with a millimeter ruler and with a digital calipter. The digital radiographs were obtained with DenOptix and Digora systems. Their images were measured with their programs tools. The real measures were obtained using K-files #20 (Dentisply- Maillefer). They were also measured using the ruler and the digital calipter. The canal length was measured from the cervical part to the apical foramina observed in the radiographs or to the anatomic apex by stereomicroscopy. Two observers made the measurements of the root canals twice (ICC= - 0.60 -0.99). DenOptix system presented the least average range in millimeters when compared to the gold standard (0.12 mm and 0.22mm). The conventional method (film) presented the largest average range (0.55mm) when measured with the ruler. The values obtained with Digora system were similar to the values obtained with the conventional method (t-Student and Friedman; p<0.05). The three radiographic methods showed differences statistically significant from the real measurements of the real canals.en_US
dc.language.isoesen_US
dc.publisherFundación Acta Odontológica Venezolanaen_US
dc.subjectDENTAL RADIOGRAPHYen_US
dc.subjectDIGITAL RADIOGRAPHYen_US
dc.subjectROOT CANALSen_US
dc.subjectENDODONTIC MEASURESen_US
dc.subjectODONTOLOGIAen_US
dc.subjectRADIOLOGIA ODONTOLÓGICAen_US
dc.subjectCANAL RADICULARen_US
dc.titleComparación entre radiografias convencionales y digitales en la medición de canales radicularesen_US
dc.typearticleen_US
dc.jtitleActa Odontológica Venezolanaen_US
dc.publication.date2010en_US
dc.volume48en_US
dc.issue2en_US
dc.spage1en_US
dc.epage9en_US
Aparece en las colecciones:Artigo de Periódico

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
art10.pdfTexto Completo144,03 kBAdobe PDFAbrir
Ver


Todos los ítems en el Repositorio de la PUCRS están protegidos por derechos de autor, con todos los derechos reservados, y están bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional. Sepa más.