Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/16366
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.advisorShinkai, Rosemary Sadami Arai-
dc.contributor.authorBarcellos, Leonardo Hoffmann de-
dc.date.accessioned2019-11-30T12:01:24Z-
dc.date.available2019-11-30T12:01:24Z-
dc.date.issued2014pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/16366-
dc.description.abstractUma análise não linear pelo Método de Elementos Finitos foi realizada com o objetivo de avaliar a influência da utilização de pilares angulados e do ponto de aplicação de carga na distribuição de tensões no osso periimplantar, no parafuso do pilar protético e no parafuso protético de cinco implantes que receberam uma Prótese do tipo Protocolo Brånemark. Para tanto, modelos vituais foram gerados simulando uma prótese total fixa com infraestrutura metálica suportada por cinco implantes em mandíbula, com a inclinação dos posteriores em 27 graus. Quatro situações foram testadas com aplicação de carga de 100N: em região de segundo pré-molar com pilares retos (RP) e angulados nos implantes distais (AP); em região de primeiro molar com pilares retos (RM) e angulados nos implantes distais (AM). As tensões Von Misses resultantes foram analisadas qualitativamente nas três regiões de interesse. Os resultados mostraram que a utilização de pilares angulados gerou uma redução nas tensões na região periimplantar, entretanto tiveram um aumento dessas nos parafusos do pilar e protético. Ainda, as magnitudes de tensões foram menores quando a carga foi aplicada em região de segundo pré-molar. Portanto, dentro das limitações deste trabalho, podemos concluir que, embora a utilização de pilares angulados possa gerar um ganho biológico pela diminuição das tensões geradas no osso periimplantar, a utilização destes pilares pode aumentar os riscos biomecânicos pelo aumento das tensões geradas nos parafusos dos pilares protéticos e nos parafusos protéticos. Além disto, conclui-se também que uma menor extensão de cantilever é, provavelmente, mais favorável por gerar menores tensões.pt_BR
dc.description.abstractThe aim of this study was to analyse the use of angled abutments and the loading region on the stress generated at the implant-bone interface, the abutment screws and the prosthetic screws of a full-arch implant supported prosthesis. A nonlinear finite element analysis was performed on models simulating a mandibular fixed prosthesis supported by five implants, with the distal ones tilted 27 degrees distally. Applying a force of 100N, four situations were tested: region of loading on the second premolar using straight abutments on all implants (RP) and using angled abutments on the distal implants (AP); and applying the load on the first molar region with straight abutments (RM); and angled abutments on the distal implants (AM). The resulting Von Mises strains were evaluated by a qualitative method in the three regions of interest. The results showed that the utilization of angled abutments on the distal implants generated lower tensions on the periimplant bone, at the same time that they presented higher strains on the abutment and prosthetic screws. The tensions were always reduced when the load was applied on the second premolar region. Within the limitations of this study, it was possible to conclude the the used of angled abutments may increase the risk of biomechanical failures on a full-arch implant supported prosthesis, although its use may also result on lower strains in the bone interface. Also, that reduced cantilevers are more favorable because of the generation of lower stresses on the bone and the protsthetic components.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.rightsopenAccessen_US
dc.subjectIMPLANTODONTIApt_BR
dc.subjectIMPLANTES DENTÁRIOS OSSEOINTEGRADOSpt_BR
dc.subjectPRÓTESE DENTÁRIApt_BR
dc.subjectODONTOLOGIApt_BR
dc.titleInfluência de pilares angulados e ponto de aplicaçao de carga em proteses tipo protocolo branemark: análise de elemento finito não linear com modelo tridimensionalpt_BR
dc.typedoctoralThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelDoutoradopt_BR
dc.degree.date2014pt_BR
dc.publisher.placePorto Alegrept_BR
Aparece en las colecciones:Dissertação e Tese

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
TES_LEONARDO_HOFFMANN_DE_BARCELLOS_COMPLETO.pdfTexto completo11,26 MBAdobe PDFAbrir
Ver


Todos los ítems en el Repositorio de la PUCRS están protegidos por derechos de autor, con todos los derechos reservados, y están bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional. Sepa más.