Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/16510
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.advisorMattiello, Rita-
dc.contributor.authorRodrigues, Carlos Alberto Sandre-
dc.date.accessioned2020-01-17T12:01:49Z-
dc.date.available2020-01-17T12:01:49Z-
dc.date.issued2019pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/16510-
dc.description.abstractIntrodução: A mensuração do percentual de gordura mediante as dobras cutâneas é um método não invasivo, factível e de baixo custo em comparação com outras técnicas de avaliação. No entanto, na população brasileira existe um número limitado de estudos que avaliam a concordância das dobras cutâneas com outras técnicas mais precisas como a bioimpedância. Objetivo: Avaliar a concordância entre as pregas cutâneas e a bioimpedância elétrica na avaliação do percentual de gordura corporal em crianças e adolescentes. Métodos: Estudo transversal que incluiu por conveniência participantes saudáveis na faixa etária de cinco a 20 anos. As dobras cutâneas foram avaliadas de forma padronizada e as equações de Slaugher 1 e 2, Huang e Goran foram utilizadas para estimação do percentual de gordura corporal. A bioimpedância foi realizada seguindo normas padronizadas no mesmo dia da avaliação das pregas cutâneas. A correlação entre as medidas foi avaliada pela correlação de Pearson e a concordância pelo método de Bland-Altman. O valor de p <0,05 foi considerado significativo. Resultados: Foram avaliadas 439 crianças e adolescentes com idade média de 11,6 ± 3,7 anos. A média de gordura corporal pela BIA foi de 22,8 ± 10,4%, em comparação com as equações Slaughter (1) 22,4 ± 8,8%, Slaughter (2) 20,4 ± 9,2%, Goran 19,6 ± 4,4% e Huang 24,7 ± 10,0%. A análise de plotagem de Bland-Altman revelou limites de concordância superiores a 8% entre a bioimpedância e as equações, excedendo o limite clinicamente aceitável predefinido a priori. Nenhuma das equações teve boa concordância com a BIA. Conclusão: Os resultados do presente estudo sugerem que a análise da espessura das dobras cutâneas e da bioimpedância não deve ser usada de forma intercambiável em crianças e adolescentes.pt_BR
dc.description.abstractBackground: The measurement of skinfolds is a non-invasive method, feasible and low cost compared to other techniques. However, in the Brazilian population there are a limited number of studies that evaluate the accuracy of skinfolds to evaluate body composition by comparison with other more precise techniques such as bioimpedance. Objective: To evaluate the agreement between skinfolds and electrical bioimpedance in the evaluation of body fat percentage. Methods: This was a cross-sectional study that included, for convenience, healthy participants aged five to 20 years. The skinfolds were evaluated in a standardized way and the Slaugher, Huang and Goran equations were used to estimate the percentage of body fat bioimpedance was performed according to standards standardized on the same day of the evaluation of the skin folds. Correlation between measurements was assessed by Pearson's correlation and agreement by the Bland-Altman method. The value of p <0.05 was considered significant. Results: 439 children and adolescents with a mean age of 11.6±3.7 years were evaluated. The mean body fat by the BIA was 22.8±10.4%, as compared to Slaughter (1) 22.4±8.8%, Slaughter (2) 20.4±9.2%, Goran 19.6±4.4% and Huang 24.7±10.0% equations. Bland-Altman plot analysis revealed limits of agreement greater than 8% between the bioimpedance and equations, exceeding the clinically acceptable limit predefined a priori. None of the equations had good agreement with the BIA. Conclusion: The results of the present study suggest that skinfolds thickness and bioimpedance analysis should not be used interchangeably in children and adolescents.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.rightsopenAccessen_US
dc.subjectPEDIATRIApt_BR
dc.subjectGORDURA ABDOMINALpt_BR
dc.subjectCOMPOSIÇÃO CORPORALpt_BR
dc.subjectMEDICINApt_BR
dc.titleConcordância entre as pregas cutâneas e a bioimpedância elétrica na avaliação da composição corporal em crianças e adolescentespt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Medicina e Ciências da Saúdept_BR
dc.degree.levelMestradopt_BR
dc.degree.date2019pt_BR
dc.publisher.placePorto Alegrept_BR
Aparece en las colecciones:Dissertação e Tese

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
DIS_CARLOS_ALBERTO_SANDRE_RODRIGUES_COMPLETO.pdfTexto completo1,15 MBAdobe PDFAbrir
Ver


Todos los ítems en el Repositorio de la PUCRS están protegidos por derechos de autor, con todos los derechos reservados, y están bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional. Sepa más.