dc.description.abstractO trabalho aborda uma correlação numérico-experimental dos fatores que podem influenciar a temperabilidade de um aço SAE 1045 submetido ao Ensaio Jominy em uma temperatura de austenitização de 850°C. Tal correlação foi feita a partir do cálculo do coeficiente de transferência de calor e os modos presentes durante o resfriamento do corpo de prova. Estes cálculos foram obtidos com base na análise térmica do ensaio, através das taxas de resfriamento. Para isso, um termopar foi instalado em uma distância próxima da extremidade do corpo de prova a fim de obter as curvas de resfriamento. Com base nestes dados foi calculada a incerteza de medição de temperatura de ± 23 °C, para uma avaliação da repetibilidade do processo, chegando ao erro de ± 10,3 °C. Devem ser levados em consideração durante o ensaio Jominy parâmetros significativos como: pressão hidráulica adequada, temperatura de austenitização com tolerância de até ± 6°C, temperatura e vazão da água. Estes parâmetros alteram as condições de transferência de calor, e também a densidade de fluxo de calor e por conseqüência o coeficiente de transferência de calor. Foi determinada a variação do coeficiente de transferência de calor em relação ao tempo h = f(t), e seu valor médio está de acordo com o valor informado na teoria, que é de aproximadamente 15,3 kW/m²K.pt_BR
dc.description.abstractThis work presents a numerical-experimental correlation of the factors that may influence the hardenability of SAE 1045 steel subjected to the Jominy end quench test at austenitizing temperature of 850 °C. This correlation was made by calculating the heat transfer coefficient and its phase‟s presents during the cooling of the specimen. These calculations were obtained based on thermal analysis of the test, through the cooling rates. A thermocouple was installed near from the edge of the specimen to obtain the cooling temperature curves. Based on these informations were estimated uncertainties of measurement temperature ± 23 °C for an evaluation of the reproducibility of the process, even an error of ± 10. 3 °C. During the Jominy test, should be considered parameters such as hydraulic pressure suitable austenitizing temperature with a tolerance of ± 6 °C, temperature and water flow. These parameters change the phase heat transfer, and also the flux density and therefore the heat transfer coefficient of heat. It was determined the variation of the heat transfer coefficient versus time h=f(t), and the average value is close to theorycal value, which is approximately 15. 3 kW/m2. K.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.subjectENGENHARIA DE MATERIAISpt_BR
dc.subjectCALOR - TRANSFERÊNCIApt_BR
dc.subjectAÇO - TRATAMENTO TÉRMICOpt_BR
dc.titleDeterminação do coeficiente de transferência de calor em um aço ABNT/SAE 1045 através do Ensaio Jominypt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia e Tecnologia de Materiaispt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2012pt_BR
dc.publisher.placePorto Alegrept_BR