Please use this identifier to cite or link to this item: https://hdl.handle.net/10923/403
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorTeixeira, Eduardo Rolimpt_BR
dc.contributor.authorMeyer, Kleber Ricardo Monteiropt_BR
dc.date.accessioned2011-12-27T14:14:09Z-
dc.date.available2011-12-27T14:14:09Z-
dc.date.issued2008-
dc.identifier.urihttp://hdl.handle.net/10923/403-
dc.description.abstractEste trabalho avaliou o efeito do laser (AsGaAl) através de torque de remoção, em diferentes períodos de cicatrização, de implantes modelo standard lisos e texturizados, colocados em tíbias de coelhos machos da raça Nova Zelândia, submetidos ou não à irradiação com laser de baixa intensidade. Para o estudo foram utilizados 16 animais, pesando entre 3,5 a 4,0 quilos, sendo inseridos dois implantes em cada tíbia, divididos em quatro grupos (controle e laser para 16 e 30 dias de cicatrização). O laser (AsGaAl) foi aplicado com comprimento de onda de 830nm, modo contínuo e potência de 100mW, sendo a aplicação pontual de 1J/cm² em três pontos e oito aplicações, com intervalo de 48 horas, iniciada imediatamente após a cirurgia de colocação dos implantes, perfazendo um total de 24J/cm². Após o período de cicatrização, os animais foram mortos, então, realizada a remoção das tíbias e, em seguida, a medição dos torques para remoção dos implantes com torquímetro elétrico digital de empunhadura manual. Os resultados de torque de remoção obtidos para os grupos controle: Implantes lisos com 16 dias (20,42±3,06Ncm) e 30 dias (27,42±19,65Ncm); implantes texturizados com 16 dias (22,67±11,07Ncm) e 30 dias (30,46±16,06Ncm). Para os grupos laser: Implantes lisos com 16 dias (19,15±4,65Ncm) e 30 dias (30,08±4,14Ncm); implantes texturizados com 16 dias (20,48±6,72Ncm) e 30 dias (23,45±10,40Ncm). A partir dos resultados da Análise de Variância Fatorial, verificou-se que existe diferença significativa para os resultados desta pesquisa sob analise do fator isolado “tempo”, onde observou-se que, no período de 30 dias, os valores do torque de remoção são superiores ao periodo de 16 dias.pt_BR
dc.description.abstractThis work evaluated the laser (AsGaAl) laser effect by torque removal method, in different healing periods, of smooth and texturized standard model implants, installed in male New Zealand rabbit tibiae, submitted or not to low intensity laser irradiation. For the study, 16 animals, weighing between 3. 5 to 4. 0 kg, with two implants in each tibia, divided in four groups (control and laser for 16 and 30 days of healing) have been used. The laser (AsGaAl) was irradiated with a wave length of 830 nm, continuous mode and power of 100 mW, and the punctual application was 1 J/cm2 in three points and eight applications, with 48 hours intervals, started immediately after the implant installation surgery, in a total of 24 J/cm2. After the healing period, the animals were sacrificed and the tibiae were removed for the implant torque removal measurements with a manual digital torquemeter. The torque removal results for the control groups were: smooth implants, 16 days, 20. 42±3. 06Ncm, and 30 days 27. 42±19. 65Ncm; texturized implants, 16 days, 22. 67±11. 07Ncm, and 30 days 30. 46±16. 06Ncm. for the laser groups, the results were, smooth implants, 16 days, 19. 15±4. 65Ncm, and 30 days, 30. 08±4. 14Ncm; texturized implants, 16 days, 20. 48±6. 72Ncm, and 30 days, 23. 45±10. 40Ncm. The Factorial Analysis of Variance showed that there is a significant difference for this research results if only the time factor is analyzed and it has been observed that, on the 30 days period, the torque removal values are higher than those for the 16 days period.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.subjectODONTOLOGIApt_BR
dc.subjectOSSEOINTEGRAÇÃO (ODONTOLOGIA)pt_BR
dc.subjectIMPLANTODONTIApt_BR
dc.subjectLASER - ODONTOLOGIApt_BR
dc.subjectANIMAIS - EXPERIÊNCIASpt_BR
dc.subjectCOELHOS - EXPERIÊNCIASpt_BR
dc.subjectIMPLANTES DENTÁRIOS OSSEOINTEGRADOSpt_BR
dc.titleAvaliação da ação do laser (AsGaAl) no torque de remoção de implantes lisos e texturizadospt_BR
dc.typedoctoralThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelDoutoradopt_BR
dc.degree.date2008pt_BR
dc.publisher.placePorto Alegrept_BR
Appears in Collections:Dissertação e Tese

Files in This Item:
File Description SizeFormat 
000408029-0.pdfTexto Completo5,17 MBAdobe PDFOpen
View


All Items in PUCRS Repository are protected by copyright, with all rights reserved, and are licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. Read more.