dc.contributor.advisorSpohr, Ana Mariapt_BR
dc.contributor.authorMasotti, Alexandre Severopt_BR
dc.date.accessioned2011-12-27T14:14:42Z-
dc.date.available2011-12-27T14:14:42Z-
dc.date.issued2005-
dc.identifier.urihttp://hdl.handle.net/10923/575-
dc.description.abstractEste estudo avaliou as porcentagens de Transmitância direta (Td) das resinas compostas microhíbridas Charisma F, Solitaire II (Heraeus Kulzer ), Intens e Tetric Ceram (Ivoclar Vivadent) e nanoparticuladas Esthet-X (Dentsply De trey) e Filtek Supreme (3M Espe) nas cores Vita A3 (Dentina) e translúcido (Esmalte), ou seus correspondentes. Foram confeccionados três corpos-de-prova para cada material e cor, de formato quadrangular com 12x12 mm de lado e espessura de 1 mm. Após fotoativação, foram realizadas três leituras por corpo-de-prova em espectrofotômetro de UV-visível HP 8453 (Hewlett-Packard), com temperatura e umidade controladas (22±2°C/50±5%). Os ângulos de incidência e leitura em 0° / 0° foram utilizados para os comprimentos de onda de 400 a 700 nm. Os espectros obtidos foram analisados quanto ao percentual médio de Td para todo o espectro, em intervalos de 20 nm, e nos comprimentos de onda de 400, 560 e 700 nm. Através de ANOVA e teste de Tukey (p=0,01) encontrou-se que a resina composta Charisma obteve as maiores porcentagens de Td em todos os espectros, exceto para a cor Esmalte em 700 nm, que ficou abaixo da resina composta Esthet-X cor Esmalte. O teste t-Student demonstrou serem significativamente maiores os percentuais de Td para os espectros das cores Translúcido, exceto para as resinas compostas Supreme, em que não diferiram, e Charisma, com porcentagens de Td significativamente maiores para a cor Dentina. Por meio de teste não paramétrico de Friedman verificou-se que todas as resinas compostas estudadas demonstraram aumento significativo de Td com o aumento do comprimento de onda, com exceção da resina composta Solitaire, cores Dentina e Esmalte, que não demonstrou diferenças significativas nos comprimentos de onda de 560 e 700 nm.pt_BR
dc.description.abstractThe present research evaluated the direct Transmittance (Td) percentages of Charisma F, Solitaire II (Heraeus Kulzer ), Intens and Tetric Ceram (Ivoclar Vivadent) microhibrid composite resins, and Esthet-X (Dentsply De trey) and Supreme (3M Espe) nanofillers composite resins in the shades Vita A3 (Dentin) and translucent (enamel), or similars. Three samples of each composite and shade were obtained with dimensions of 12 x 12 mm and 1 mm thick. After light activation, three measurements for each sample were done with an UV-visible spectrophotometer HP 8453 (Hewlett-Packard) at controlled temperature and humidity (22±2°C / 50±5%). The incidence and readin g configuration used 0° / 0° angles between wavelengths of 400 and 700 nm. The spectra were analyzed by mean values for the percent Td at intervals of 20 nm and in the wavelengths of 400, 560 and 700 nm. ANOVA and Tukey test (p=0,01) showed that Charisma composite resin had the highest mean percentages of Td at all spectra and shades, except for shade Enamel at 700 nm, in wich Esthet-X had higher mean percentages of Td. The t-Student test showed significant higher mean percentages of Td for translucent shade spectra, except for Supreme composite resin that was not significant different and Charisma which dentin shade had significant higher mean percentages of Td. By the non-parametric Friedman test all the composite resins showed significant increment in the mean percentages of Td with higher wavelength, except for Solitaire II, shades Dentin and Enamel which 560 and 700 nm means didn't show statistical difference.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.subjectODONTOLOGIApt_BR
dc.subjectDENTÍSTICApt_BR
dc.subjectRESINAS COMPOSTASpt_BR
dc.subjectESPECTROFOTOMETRIApt_BR
dc.subjectMATERIAIS DENTÁRIOSpt_BR
dc.titleAvaliação da transmitância direta de resinas compostas por meio de espectrofotometria de UV-visívelpt_BR
dc.typedoctoralThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelDoutoradopt_BR
dc.degree.date2005pt_BR
dc.publisher.placePorto Alegrept_BR