Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/7559
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.advisorShinkai, Rosemary Sadami Arai
dc.contributor.authorSchneider, Danilo Renato
dc.date.accessioned2015-09-05T02:05:04Z-
dc.date.available2015-09-05T02:05:04Z-
dc.date.issued2014pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/7559-
dc.description.abstractEste trabalho objetiva investigar a influência da normalização dos níveis de cinza em tomografias cone beam (CBCT) e multislice (MSCT). Imagens DICOM (Digital Imaging and Communications in Medicine) de 37 sítios ósseos (18 pacientes) foram analisadas. As tomografias CBCT foram realizadas em 5 diferentes aparelhos e as tomografias MSCT foram obtidas em um único tomógrafo. As medições dos níveis de cinza foram feitas em duas regiões de interesse; ROI1 - osso alveolar (cortical e medular) e ROI2 - osso medular separadamente, de 3 formas distintas: sem normalização (RAW), normalização de toda a imagem (ALL) e normalização da região de interesse apenas (ROI). Análise descritiva com coeficiente de variação (CV) e teste ANOVA seguido de Tukey foi realizado. Para as MSCT, a média dos níveis de cinza da ROI1 aumentaram levemente de 121,9+-17,13 (RAW) para 125,0+-15,74 (ALL) (p>0,05) e reduziram para 104,8+-15,20 (ROI) (p<0,0001). O CV variou de 14,05%, para 12,59% and 14,50%, respectivamente. Na ROI2 a média aumentou de 95,11+-13,96 (RAW) para 99,40+-13,62 (ALL) e 102,5+-17,86 (ROI) (p=0,0678). O CV foi de 14,67% para 13,71% e 17,43%, respectivamente. No grupo CBCT, a média de ROI1 aumentou significativamente de 91,73+-32,17 (RAW) para 135,2+-36,06 (ALL) e 118,7+-18,65 (ROI) (p<0,0001), com o CV diminuindo de 35,06% para 26,68% e 15,71%, respectivamente. A média da ROI2 foi 81,23+-34,36, 115,3+-28,53 and 109,4+-17,47, respectivamente (p=0,0002), com um CV reduzindo de 42,30% (RAW) para 24,74% (ALL) e 15,97% (ROI). Desta forma, foi demonstrada a redução das discrepâncias entre diferentes aparelhos e da variabilidade entre exames com a utilização da normalização de intensidade de exames CBCT e MSCT na avaliação da qualidade óssea para implantes dentais.pt_BR
dc.description.abstractThis paper aims to investigate the influence of normalization in cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) grey level to assess bone quality of recipient sites for dental implants. DICOM (Digital Imaging and Communications in Medicine) images from 37 bone sites (18 patients) were analyzed. CBCT was performed with 5 different CBCT devices and MSCT in a single multislice CT scanner. Measurements of mean grey level were performed in two regions of interest; ROI1 - alveolar bone (cortical and trabecular) and ROI2 - cancellous bone separately with 3 tested forms: no normalization (RAW), normalization of the whole image (ALL) and normalization of the region of interest only (ROI). Descriptive analysis with coefficient of variation (CV) and one-way ANOVA followed by Tukey was performed. For MSCT, ROI1 mean grey level slightly increased from 121. 9+-17. 13 (RAW) to 125. 0+-15. 74 (ALL) (p>0. 05) and reduced to 104. 8+-15. 20 (ROI) (p<0. 0001). CV varied from 14. 05%, to 12. 59% and 14. 50%, respectively. ROI2 increased from 95. 11+-13. 96 (RAW) to 99. 40+-13. 62 (ALL) and 102. 5+-17. 86 (ROI) (p=0. 0678). CV was 14. 67% to 13. 71% and 17. 43%, respectively. In CBCT group, ROI1 meaningfully raise from 91. 73+-32. 17 (RAW) to 135. 2+-36. 06 (ALL) and 118. 7+-18. 65 (ROI) (p<0. 0001), with CV decreasing from 35. 06% to 26. 68% and 15. 71%, respectively. ROI2 was 81. 23+-34. 36, 115. 3+-28. 53 and 109. 4+-17. 47, respectively (p=0. 0002), with a CV reducing from 42. 30% (RAW) to 24. 74% (ALL) and 15. 97% (ROI). Therefore, the use of intensity normalization of CBCT and MSCT examinations was demonstrated on reducing discrepancies between different scanners and inter-exams variability in bone quality assessment for dental implants.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.rightsopenAccessen_US
dc.subjectODONTOLOGIApt_BR
dc.subjectIMPLANTODONTIApt_BR
dc.subjectPRÓTESE DENTÁRIApt_BR
dc.subjectTOMOGRAFIA COMPUTADORIZADApt_BR
dc.titleInfluência da normalização dos níveis de cinza em tomografias computadorizadas Cone Beam e multislice na avaliação da qualidade ósseapt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2014pt_BR
dc.publisher.placePorto Alegrept_BR
Aparece en las colecciones:Dissertação e Tese

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
000474617-Texto+Completo-0.pdfTexto Completo1,11 MBAdobe PDFAbrir
Ver


Todos los ítems en el Repositorio de la PUCRS están protegidos por derechos de autor, con todos los derechos reservados, y están bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional. Sepa más.