dc.description.abstractThe purpose of this study was to assess the influence of two light units, a light-emitting diode (LED) and a plasma arc light (PAC), on the shear bond strength (SBS) of brackets bonded to enamel. Ninety bovine teeth were divided into six groups, according to the light-curing unit and exposure times used. In the LED (Ortholux; 3M-Unitek) group, the specimens were light cured for 5, 10, and 15 seconds. In the PAC (Apollo 95E; DenMed Technologies) group, the specimens were light cured for 3, 6, and 9 seconds. The brackets were bonded with Transbond XT (3M-Unitek), stored in distilled water at 37°C for 24 hours and then submitted to SBS testing in a universal testing machine. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the teeth. According to analysis of variance and Tukey multiple comparisons test, the highest mean SBS was obtained with the LED at 15 seconds (16.68 MPa), which did not significantly differ from the LED 10 (14.76 MPa) or 5 (13.92 MPa) second groups (P > 0.05). The LED 10 and 5 second groups were not significantly different from the PAC 9 second group (12.66 MPa) or from the PAC 6 second group (9.96 MPa). The lowest mean SBS was obtained with the PAC 3 second group (8.29 MPa), which did not differ significantly from the PAC 6 second group. The method of light curing did not influence the ARI, with score 3 predominant. The LED at 5 seconds and the PAC at 3 seconds provided sufficient mean SBS to resist either orthodontic or masticatory forces.en_US
dc.language.isoen_USen_US
dc.publisherEuropean Orthodontic Societyen_US
dc.subjectLIGHT-CURING UNITSen_US
dc.subjectDENTALen_US
dc.subjectLIGHT-EMITTING DIODEen_US
dc.subjectODONTOLOGIApt_BR
dc.subjectDENTESpt_BR
dc.subjectESTÉTICA DENTÁRIApt_BR
dc.subjectCLAREAMENTOpt_BR
dc.titleEffect of curing time on the bond strength of a bracket-bonding system cured with a light-emitting diode or plasma arc lighten_US
dc.typearticleen_US
dc.identifier.doi10.1093/ejo/cjq027en_US
dc.identifier.pmid20558589en_US
dc.publisher.placePorto Alegrept_BR
dc.jtitleEuropean Journal of Orthodonticsen_US
dc.publication.date2011en_US
dc.volume33en_US
dc.issue1en_US
dc.spage55en_US
dc.epage59en_US