Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10923/886
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.authorCerveira, Guilherme Pessôa-
dc.contributor.authorBerthold, Telmo Bandeira-
dc.contributor.authorSouto, André A.-
dc.contributor.authorSpohr, Ana Maria-
dc.contributor.authorMarchioro, Ernani Menezes-
dc.date.accessioned2012-04-24T13:47:02Z-
dc.date.available2012-04-24T13:47:02Z-
dc.date.issued2010-
dc.identifier.issn0141-5387en_US
dc.identifier.urihttp://hdl.handle.net/10923/886-
dc.description.abstractThe purpose of this study was to assess the influence of two light units, a quartz-tungsten-halogen (QTH) and a light-emitting-diode (LED) on the hardness and degree of conversion of an orthodontic composite resin.Sixty specimen disk were prepared from Transbond XT composite resin (3M-Unitek) and light-cured for 10, 20 and 30 seconds with a QTH light-curing unit (Curing Light XL 3000, 3M-Unitek) or with a LED light-curing unit (Ortholux, 3M-Unitek) for 5, 10 and 15 seconds. The composite resin polymerization was evaluated by infrared spectrophotometry (FTIR) and Knoop hardness number (KHN). The results were statistically analyzed using analysis of variance and Tukey multiple comparisons test (alpha=0.05). The highest KHN were obtained with the QTH at 30 (25.19 KHN) and 20 (24.01) seconds, which did not differ statistically, and with the LED 15 second (21.86) group. The QTH 10 second group (20.53) did not differ statistically from the QTH 20 second or LED 5, 15 (19.96) or 10 second (18.95) groups. According to FTIR, there was no statistical difference for the degree of conversion among the groups, QTH 10 (43.42%), QTH 20 (46.12%), QTH 30 (45.30%), LED 10 (47.02%) or LED 15 (47.24%) seconds. The lowest degree of conversion was obtained for the LED 5 second group (38.97%), which did not differ statistically from the QTH 10 second group. Light-curing with the LED resulted in a reduction of 50 per cent in the time recommended for use of the QTH light with the composite resin Transbond XT.en_US
dc.language.isoen_USen_US
dc.publisherOxforden_US
dc.subjectCOMPOSITE RESINen_US
dc.subjectLIGHTen_US
dc.subjectDEGREE OF CONVERSIONen_US
dc.subjectHARDNESSen_US
dc.subjectODONTOLOGIApt_BR
dc.subjectCERÂMICA DENTÁRIApt_BR
dc.subjectRESISTÊNCIA DOS MATERIAIS (ODONTOLOGIA)pt_BR
dc.titleDegree of conversion and hardness of an orthodontic resin cured with a light-emitting-diode and a quartz-tungsten-halogen lighten_US
dc.typearticleen_US
dc.identifier.doi10.1093/ejo/cjp048en_US
dc.publisher.placePorto Alegrept_BR
dc.jtitleEuropean Journal of Orthodonticsen_US
dc.publication.date2010en_US
dc.volume32en_US
dc.issue1en_US
dc.spage83en_US
dc.epage86en_US
Aparece en las colecciones:Artigo de Periódico

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Cerveira et al 2010.pdfTexto Completo133,88 kBAdobe PDFAbrir
Ver


Todos los ítems en el Repositorio de la PUCRS están protegidos por derechos de autor, con todos los derechos reservados, y están bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional. Sepa más.