Please use this identifier to cite or link to this item: https://hdl.handle.net/10923/481
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorTeixeira, Eduardo Rolimpt_BR
dc.contributor.authorSilva, Fabrício Dorigon dapt_BR
dc.date.accessioned2011-12-27T14:14:22Z-
dc.date.available2011-12-27T14:14:22Z-
dc.date.issued2010-
dc.identifier.urihttp://hdl.handle.net/10923/481-
dc.description.abstractEste estudo in vitro teve como objetivo comparar os valores de pré-carga e torque de remoção de três tipos de parafusos de fixação de pilares para próteses unitárias submetidos ao teste de ciclagem mecânica. Foram utilizados 10 implantes hexágono externo (Conexão®, Sistemas de Prótese Ltda. , São Paulo, Brasil) com 4,0mm de diâmetro e 15,0mm de comprimento, nos quais foram cimentadas 30 coroas metálicas sobre abutments Cera One®, fixados com seus respectivos parafusos de ouro, titânio e titânio com tratamento de superfície (Torq-Tite®). Os parafusos foram inseridos e registrou-se a pré-carga inicial. Após cimentação das coroas, as amostras foram posicionadas na cicladora mecânica e submetidas a 400 mil ciclos com freqüência de 1 ciclo/segundo e carga de 100N. Após o teste, foi avaliado o valor de pré-carga produzido com a utilização da célula medidora de carga e extensômetros. Para mensuração dos torques de aperto e remoção, utilizou-se dispositivo eletrônico de controle de torque. Os parafusos de ouro apresentaram os maiores valores de pré-carga (pré-ciclagem 341,00±78,53 N; pós-ciclagem 284,60±72,81 N) em relação aos parafusos de titânio (pré-ciclagem 235,00±27,39 N; pós-ciclagem 196,00±29,66 N) e tratado (pré-ciclagem 284,00±70,92 N; pós-ciclagem 195,00±69,28 N). Para os valores de torque de remoção, os maiores registros foram encontrados para o grupo titânio (21,00 ± 0,79 Ncm), seguido do grupo ouro (18,06±1,94 Ncm) e tratado (16,64±1,38 Ncm). Após análise estatística, ANOVA (p<0,10) e T-Student (p<0,05), foram encontradas diferenças significativas entre os três grupos, para pré-carga, pré e pós-ciclagem e torque de remoção. Devido aos maiores valores de pré-carga obtidos nos resultados do estudo, sugere-se que os parafusos de ouro sejam os mais indicados para obtenção de estabilidade da junta pilar-implante.pt_BR
dc.description.abstractThis study was aimed to compare the preload and removal torque values of three types of screw for transmucosal abutment attachment to single implantsupported prosthesis submitted to cyclic loading test. Ten external hex fixtures (Conexão®, Sistemas de Prótese Ltda. , São Paulo, Brazil) were used, presenting 4,0mm in diameter and 15,0mm in length. Thirty metal crowns were cemented over the abutments Cera One® and attached with its gold, titanium and surface-treated titanium (Torq-Tite®) screws. The screws were attached and the initial preload was recorded. After crown cementation, the samples were placed in a cyclic loading machine and submitted to 400 thousand cycles and a load of 100N. After the test, the preload values were measured through a strain gauge and a measurement cell. Initial and removal torques were measured with an electronic torque control device. Gold screws exhibited the highest preload values (before cyclic 341,00±78,53 N; after cyclic 284,60±72,8 N), followed by surface-treated titanium screws (before cyclic 284,00±70,92 N; after cyclic 195,00±69,28 N) and titanium screws presented the lowest results (before cyclic 235,00±27,39 N after cyclic 196,00±29,66 N). Regarding torque removal values, titanium screws presented the highest values (21,00 ± 0,79 Ncm), followed by gold screws (18,06 ± 1,94 Ncm) and surface-treated titanium screws (16,64 ± 1,38 Ncm). After statistical analysis, ANOVA (p<0,05) e TStudent (p<0,05), significant differences were found between groups for preload, before and after cyclic loading and removal torque. Considering the results, gold screws are the most indicated samples in obtaining joint stability.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.subjectODONTOLOGIApt_BR
dc.subjectIMPLANTODONTIApt_BR
dc.subjectPRÓTESE DENTÁRIApt_BR
dc.subjectMATERIAIS DENTÁRIOSpt_BR
dc.subjectFIXAÇÃO RÍGIDA (ODONTOLOGIA)pt_BR
dc.titleAvaliação da pré-carga e torque de remoção de três parafusos de pilares para próteses unitárias implantossuportadas após ciclagem mecânicapt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2010pt_BR
dc.publisher.placePorto Alegrept_BR
Appears in Collections:Dissertação e Tese

Files in This Item:
File Description SizeFormat 
000422731-0.pdfTexto Completo3,91 MBAdobe PDFOpen
View


All Items in PUCRS Repository are protected by copyright, with all rights reserved, and are licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. Read more.